Model
Specification
|
SCN-600-12
|
SCN-600-13.5
|
SCN-600-15
|
SCN-600-24
|
SCN-600-27
|
SCN-600-48
|
DC Output Voltage
|
12V
|
13.5V
|
15V
|
24V
|
27V
|
48V
|
Iutput Voltage Error
|
± 1%
|
± 1%
|
± 1%
|
± 1%
|
± 1%
|
± 1%
|
Rated Output Current
|
50A
|
44A
|
40A
|
25A
|
22A
|
12.5A
|
Output Current Range
|
0-50A
|
0-44A
|
0-40A
|
0-25A
|
0-22A
|
0-12.5A
|
Tripple and Noise
|
240mVp-p
|
240mVp-p
|
240mVp-p
|
240mVp-p
|
240mVp-p
|
300mVp-p
|
Voltage Adj range
|
±5.0% typical adjustment by potentiometer 20~100% adjustment by 1~5VDC external control
|
Iniet Stability
|
± 0.5%
|
± 0.5%
|
± 0.5%
|
± 0.5%
|
± 0.5%
|
± 0.5%
|
Tolerance Voltage
|
± 1%
|
± 1%
|
± 1%
|
± 1%
|
± 1%
|
± 1%
|
DC Output Power
|
600W
|
594W
|
600W
|
600W
|
594W
|
600W
|
Efficiency
|
84%
|
84%
|
83%
|
85.5%
|
86.5%
|
87%
|
AC Input Voltage Range
|
90 ~ 130VAC / 180 ~ 260VAC selected by switch, 260 ~ 370VDC
|
Input Current
|
11A / 115VAC 7.0A / 230VAC
|
AC Inrush Current
|
Cold-Start Current: 60A / 230VAC
|
Leakage Current
|
3.5mA/240VAC
|
Overload Protection
|
110 ~ 135% rated output power,Current limiting, delay shut down o/p voltage, re-power on to recover
|
Over Voltage Protection
|
110 ~ 135% follow to output set up point, Shut down o/p voltage, re-power on to recover
|
High Temperature Protection
|
>100℃ / measure by heat sink, near transformer,Shut down o/p voltage, re-power on to recover
|
Temperature Coefficient
|
± 0.04% /℃ (0~50℃)
|
Start, Rise, Hold time
|
800ms, 50ms, 16ms at full load
|
Vibration
|
10 ~ 200Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
|
Withstand Voltage
|
I/P-O/P, I/P-FG:1500VAC
|
Isolation Resistance
|
I/P-O/P, I/P-FG, 100M Ohms / 500VDC / 25 ℃/ 70% RH
|
Working Temperature and Humidity
|
`-10℃~+60℃ (Refer to Output Derating Cutve), 20%~90%RH
|
Storage Temperature and Humidity
|
`20℃~+85℃, 10%~95%RH
|
MTBF
|
120Khrs min. MIL-HDBK-217F (25℃ )
|
Overall Dimension
|
291*132*68 mm
|
Weight
|
2.65 kgs
|
Special function
|
DC voltage adj., Remote sensing, remote control, parallel operation (refer to terminal instruction manual)
|
Safety Standards
|
CE
|
EMC Standards
|
Meet FCC Part 15J Conduction class A
|